← Back to Clause Explorer
8.3.3.3IATF 16949 ONLYIATF 16949:2016

Special characteristics (IATF only)

Plain-language summary

Identify special characteristics through a defined process — from risk analysis, customer designations and your own knowledge — and carry them visibly through every document: drawings, FMEA, control plan, work instructions.

What the clause is really asking

A documented process must establish special characteristics (customer-designated plus those from your own risk analysis), include them in the control plan and FMEA with the appropriate markings, and apply customer-specified definitions and symbols where they exist.

What auditors look for

Auditors run the correlation check: special characteristics consistent across drawing, PFMEA, control plan and instructions, with the right symbols, and controls genuinely tighter at those steps (capability studies, error-proofing, increased frequency).

Typical evidence

Special characteristics identification procedure; correlation matrix; FMEA/control plan markings; capability evidence on SCs.

How to comply — recommendations

Maintain one SC correlation matrix per part and make it a PPAP document. Any document change touching an SC triggers a matrix check — one rule that prevents the most common automotive audit finding.

Common nonconformities

SC marked in FMEA but not control plan (or vice versa); no process for self-identified SCs; SCs treated identically to standard characteristics in practice.

Related clauses

Builds on ISO 9001 8.3.3; links IATF 8.2.3.1.2

Qlause provides interpretive guidance only and is not a substitute for the standard. Refer to your licensed copy of ISO 9001 / IATF 16949 for the authoritative text.